Intel's I/O AT is not a TOE killer

Networked storage still needs TOEs - and Intel has one

I've just finished reading a couple of Intel papers on I/O AT from a networked storage point of view and wonder whether Intel is, to be blunt, not grasping the right end of the stick? Intel's Pat Gelsinger, senior vice-president of Intel's new Digital Enterprise Group, said this regarding I/O AT: " "We looked at TOEs [network interface cards with TCP/IP offload engines] and found they did no good in most cases. I/O AT increases data exchange by at least 30 percent for many different kinds of server traffic." Exit TOEs; enter I/O AT.

Just to remind us what I/O AT is about; with it the TCP/IP protocol stack is optimised for the (Intel) processor, copying of packet header and payload data is supported in an Intel chip set, with parallel processing and direct-memory access being a feature of an Intel network controller. Intel is reported as claiming: 'putting the TOE capabilities inside a chip instead of relying on a separate card increased performance in 90 percent of the applications it tested."

So TOES are not necessary. Or are they?

The Intel white paper
The first paper is 'Accelerating High -Speed Networking with Intel I/O Acceleration Technology'.

In it the Intel seems to be saying that TOEs are not needed because the actual CPU overhead involved with TCP/IP processing is small. Most of the time is spent fetching and copying packet header and payload data. But it also says that TOEs are effective with data warehousing and 'high-performance databases', also storage backup and retrieval and 'enterprise databases' - all of which use large data payloads with packets of 8KB or more.

Intel asserts TOEs are not needed for smaller network data payloads, web services, messaging traffic, communications within clusters, RFID and real time data with data payload sizes typically less than 1KB. Unless you are doing backup or enterprise database work you don't need TOEs; that's Intel's message.

But, correct me if I'm wrong, no one in the storage industry is suggesting using TOE NICs for RFID or messaging or, indeed on client PCs, as Intel clearly implies; Frank Spindler, VP of technology programs for Intel, has said that I/O AT can improve interaction between networked clients and servers by up to 30 percent.

No storage industry supplier is suggesting that TOEs should be used to connect clients to servers. The storage industry says TOEs are used to connect servers to networked storage and that means iSCSI SANs or NAS over Ethernet.

And, correct me if I'm missing the plot, but aren't virtually all networked storage data accesses about packets substantially larger than ones with less than a 1KB data payload?

Alacritech spokesperson Valdis Hellavik said: "Your thoughts about Intel are right on the money ... they're right on target."

So what is Intel playing at? Is it playing up an I/O acceleration technology as being generally applicable to storage access when it fact it doesn't apply to networked storage access at all?

Technical paper
The second paper is 'Intel I/O Acceleration Technology'. In it Intel talks about increasing storage I/O performance and says a key element of its I/O AT solution includes use of a 'storage processor' (the new Intel IOP333 storage processor) to retain this workload as a peripheral function'. The workload being data transfers to and from an application. No performance numbers are given. So we might assume that such a storage processor does not in fact increase server networked data access over Ethernet at all. It's only pertinent to direct-attached disk performance.

Direct-attach disk acceleration
Intel's web site states: ' Intel Application Accelerator has the ability to substantially increase the storage subsystem speed by increasing the data rate, from the disk to the system, using special software technologies. Consequently, all boot processes, except for the BIOS, are inherently accelerated.' So access to directly-attached disks can be accelerated. But this Application Accelerator does not apply to networked storage access and is separate from I/O AT.

TOE card review
Techworld reviewed a iSCSI TOE card from Adaptec. Here's what our review said about CPU utilisation: 'Adaptec scores heavily when it comes to processor utilisation. For the single disk and four disk striped array tests Iometer reported CPU utilisation as 18 per cent and 19 per cent respectively when using the Microsoft (software) initiator but with Adaptec in charge these figures dropped to only 3.1 and 3.5 per cent. We saw the biggest improvement when running the same tests on a Pentium III 866MHz system loaded with Windows 2000 Server which saw a 25 per cent reduction in CPU overheads."

The reduction in CPU burden was substantial. This, on the face of it, doesn't square with Intel's assertion that actual CPU processing is only a small proportion of TCP/IP packet processing.

Intel's own TOE
It might surprise you but Intel has its own TOE product. Its PRO/1000 T IP storage adapter competes with iSCSI TOEs from companies such as Adaptec and Alacritech. Blaine Kohl, marketing director for high-end server connections in Intel's LAN Access Division, is reported as saying the PRO/1000 T uses a full-TCP/IP offload engine design in which TCP/IP and iSCSI protocol processing is offloaded to Intel's IOP310 chipset (based on Intel's XScale architecture) and 82544EI Gigabit Ethernet controller. Intel claims CPU utilization of 3% to 5% or less from its own testing - that roughly concurs with our test of the Adaptec card.

Clearly the IOP310 functions as a TCP/IP offload engine (TOE). Has Intel now disowned its own TOE? Is its I/O AT a TOE amputation message?

I/O AT and iSCSI acceleration
It appears likely that Intel's I/O AT is simply not applicable to the iSCSI storage market. Contrary to Intel's general message TOEs are still most definitely needed to accelerate I/O over networked storage links. I/O AT may well help networked clients talk more quickly with application servers but that has nothing to do with networked storage access. Intel has not been able to respond to questions on this matter.

The iSCSI storage suppliers can use their TOEs to give Intel I/O AT a boot into touch, until and if Intel comes up with something that truly replaces TOEs for networked storage.


What are your views on this subject? Use the form below to post a comment on this article up to 500 characters.


Characters remaining: 500

Related Storage news

HP tool offers continous laptop backup

Set it and forget.

Intel fixes drive bricking firmware update for flash drives

Company to re-release SSD software

IBM offers Lotus Symphony on Keepod USB devices

Thin USB device uses VMware to provide secure access to the Lotus suite

Sun claims record-breaking storage array

Says Storage 7000 is fastest on the planet

Related Storage reviews



Email this article to a friend or colleague:


PLEASE NOTE: Your name is used only to let the recipient know who sent the story, and in case of transmission error. Both your name and the recipient's name and address will not be used for any other purpose.

Techworld White Papers

Database security: Preventing enterprise data leaks at the source

IDC discusses the growing internal threats to business information, the impact of government regulations on the protection of data, and how enterprises must adopt database security best practices...

Download Whitepaper

Service-oriented security

SOA has become an integral part of enterprise software by providing a framework to efficiently develop software as services that is easily sharable, reusable, and integrated. No where is the need more apparent than in the Identity Management space. Welcome to the age of Service-Oriented Security (SOS).

Download Whitepaper

Data protection prospective vendor checklist

Organisations need a way to map business needs against all these challenges in procuring a technical solution. To help, SANS has developed the following Prospective Vendor Checklist.

Download Whitepaper

Unlock the power of the mainframe

This whitepaper presents the notion of CICS as an integration hub based on a component-based, service-oriented architecture supporting Web services. Highlights will review the challenges and contrasted support for Web services natively in CICS.

Download Whitepaper

Techworld UK - Technology - Business

COLT White Paper

Are all VoIP services the same?

Questions to ask your service provider to ensure you get the VoIP service you need
With careful choice of partner, your business can have all the advantages of VoIP access - reduced costs, flexibility and simplicity - without the drawbacks.
This white paper is your guide to ensure you get right the VoIP service and details the pitfalls which businesses would do well to avoid.

Download white paper
BMC

Ride the express lane in the journey to speed ITIL adoption

Explore the challenges in making the journey to ITIL and the criteria for selecting consulting services
By following ITIL practices, your IT organisation will become more closely integrated with the business. We recommend making the journey to ITIL in a sequence of six incremental steps, the phases of which are driven through execution of a strategic transformational roadmap.

Download white paper

Webcast: IT Financial Management: Cost Optimisation for Efficiency and Agility.
On Demand Webcast
Join this webcast to learn about the techniques and technologies that can help you prove the value of IT to the business by understanding the true cost of today's IT services and those that will be necessary to deliver future success.

Register Today

Site Map

IDG Network

* *